International Journal of Medical Informatics
Volume 79, Issue 4 , Pages e24-e34, April 2010

Usability testing of mobile ICT for clinical settings: Methodological and practical challenges

  • Dag Svanæs

      Affiliations

    • Department of Computer and Information Science, Norwegian University of Science and Technology, Trondheim, Norway
    • Corresponding Author InformationCorresponding author at: Department of Computer and Information Science, Norwegian University of Science and Technology, 7491 NTNU Trondheim, Norway. Tel.: +47 91897536.
  • ,
  • Ole Andreas Alsos

      Affiliations

    • Department of Computer and Information Science, Norwegian University of Science and Technology, Trondheim, Norway
  • ,
  • Yngve Dahl

      Affiliations

    • Department of Computer and Information Science, Norwegian University of Science and Technology, Trondheim, Norway
    • Telenor Research & Innovation, Telenor ASA, Trondheim, Norway

Received 11 April 2008; accepted 30 June 2008. published online 30 January 2009.

Abstract 

Background

While much is known about how to do usability testing of stationary Electronic Patient Record (EPR) systems, less is known about how to do usability testing of mobile ICT systems intended for use in clinical settings.

Aim

Our aim is to provide a set of empirically based recommendations for usability testing of mobile ICT for clinical work.

Method

We have conducted usability tests of two mobile EPR systems. Both tests have been done in full-scale models of hospital settings, and with multiple users simultaneously. We report here on the methodological aspects of these tests.

Results

We found that the usability of the mobile EPR systems to a large extent were determined by factors that went beyond that of the graphical user interface. These factors include ergonomic aspects such as the ability to have both hands free, and social aspects such as to what extent the systems disturbs the face-to-face interaction between the health worker and the patient.

Conclusions

To be able to measure usability issues that go beyond what can be found by a traditional stationary user interface evaluation, it is necessary to conduct usability tests of mobile EPR systems in physical environments that simulate the conditions of the work situation at a high level of realism. It is further in most cases necessary to test with a number of test subjects simultaneously.

Keywords: Medical informatics, Electronic patient records, Mobile ICT, Usability evaluation

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1386-5056(08)00110-X

doi:10.1016/j.ijmedinf.2008.06.014

International Journal of Medical Informatics
Volume 79, Issue 4 , Pages e24-e34, April 2010